The ignition source, as a heat source providing combustion reaction, is the direct cause of inducing dust explosion accidents. In industrial production, there are various types of ignition sources around each process equipment or accessory component. According to incomplete statistics, the ignition methods that cause dust explosions mainly include impact or friction, electrostatic sparks, welding or melting sparks, spontaneous combustion sparks, open flames, metal overheating, and electrical sparks according to the frequency of accidents. Overall, the common ignition sources in explosive dust environments are:



flame

Open flames are important ignition sources for industrial fire and explosion accidents, and smoking, industrial hot work (such as gas cutting and welding), heating furnaces, etc. are all effective ignition sources for explosive hazardous environments. Usually, in safety management, enterprises should absolutely prohibit the existence of open flame ignition sources in explosive hazardous areas, and establish a sound system for hot work operations. If open flame operations are necessary, they should be strictly carried out in accordance with the hot work operation system.


 



High temperature objects

The hot surface of high-temperature objects is a potential ignition source for explosive hazardous environments, which can be divided into two categories: electrical equipment hot surfaces and non electrical equipment hot surfaces. In industrial production, heating equipment, heating devices, motors/lamps, etc. are prone to become high-temperature objects and should be explosion-proof treated in accordance with the relevant requirements of GB3836 and GB12476 series standards. Mechanical equipment such as internal combustion engines, gearboxes, bearings and other mechanical components or assemblies are also prone to forming high-temperature hot surfaces under normal or fault conditions. In industrial safety production, ignition hazard assessment and detection should be carried out in accordance with GB25286 and related series standards.


 



Electrical spark

Electrical spark is a potential ignition source carried by electrical equipment itself, which is a breakdown discharge between electrodes. It is usually generated when the electrical circuit is disconnected or short circuited, the electrical equipment starts braking, or the electrical equipment runs overloaded.


 



electrostatic discharge

According to the forms of static electricity generation, static electricity can be divided into various forms of electrification, such as contact friction separation electrification, electrostatic induction electrification, and electromagnetic induction electrification; According to the properties of charged bodies, they can be divided into solids, liquids, gases, powders, and human body charges. In explosive dust environments, various non-metallic components or their non-metallic parts are prone to generate frictional static electricity, while various electromagnetic inductions make metal components prone to inducing static electricity. As an important participant in explosive dust environments, the human body itself is an important source of static electricity generation. Therefore, various types of static electricity are widely present in dust explosion hazardous environments, and effective measures should be taken to avoid them.


 



Impact and Friction

The impact and friction between mechanical equipment or components are also important ignition sources in combustible dust environments. During the process of impact and friction between metal components, metal sparks or friction on high-temperature surfaces are easily generated, which can ignite explosive hazardous environments. Therefore, all types of mechanical equipment or components used in explosive hazardous areas should undergo an assessment of their ignition hazard, analyze the risk of the equipment itself becoming an effective ignition source, and take measures to avoid it, ensuring the safe use of mechanical equipment in explosive hazardous environments.


 



chemical reaction

Chemical reactions, especially self heating reactions, are potential ignition sources in explosive hazardous environments, such as aluminum iron reactions, oxidative combustion, etc. A large amount of freely accumulated dust, such as coal mines, flour and corn starch grain warehouses, often self ignite and catch fire due to the accumulation of dust.


 



thunder

Lightning is one of the biggest threats to explosive dust environments in nature. The huge discharge current generated during lightning discharge has great destructive power and is also prone to dust explosion accidents. Therefore, the factory buildings (structures) in workplaces with dust explosion hazards must be equipped with lightning protection systems in accordance with the "Code for Design of Lightning Protection of Buildings" (GB50057-2010) and can be grounded.


Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號(hào)
Service Hotline
18924609560
點(diǎn)擊這里給我發(fā)消息 1354407946
點(diǎn)擊這里給我發(fā)消息 1354407946
主站蜘蛛池模板: 奇米影视四色首页手机在线 | 黑人中文字幕在线精品视频站 | 免费在线公开视频 | 六月丁香综合 | 青青草国产青春综合久久 | 丁香六月五月婷婷 | 婷婷四房综合激情五月性色 | 韩国剧情片的网址 | 国产成人一区免费观看 | 情之债电视剧全集 | 久久精品国产亚洲网站 | 国产成人精品日本亚洲网站 | 成人国内精品久久久久影 | 午夜成人影视 | 私人免费电影影院 | 国产精品酒店视频 | 99在线精品视频在线观看 | 黄色短视频在线播放 | 久久综合五月天婷婷伊人 | 久久久高清免费视频 | 大陆高清自拍 | 欧美网站视频 | 欧美一级欧美一级在线播放 | 99在线视频免费观看 | 国产精品久久久久久免费 | 久久精品亚洲乱码伦伦中文 | 人人狠狠综合久久亚洲婷婷 | 国产精品九九九久久九九 | 国产一极毛片 | 国产精品玖玖 | 快播在线看 | 久久久久久久久久久久福利 | 久久久99精品免费观看 | 两性视频网站 | 日本精品视频一区 | 奇米第四狠狠777高清秒播 | 99综合在线 | 99在线热播| 久久久久久久男人的天堂 | 免费一级a毛片在线播 | 国产精品视频久久久久久 |